Cardiovascular implantable electronic device infection

From IDWiki

Background

  • Ranges from local pocket infection to bacteremia to endocarditis

Definitions

  • Isolated pocket erosion: device or lead exposed through the skin, with or without signs of infection
  • Isolated generator pocket infection: localized erythema, swelling, pain, tenderness, warmth, or drainage, with negative blood cultures
  • Lead infection: lead vegetation with positive blood cultures

Microbiology

Epidemiology

  • Occurs in about 2 per 1000 device-years

Risk Factors

Clinical Manifestations

  • Frequently infected at time of implantation, replacement, or surgical manipulation
  • Often starts with generator pocket infection, then infection tracts back up the leads to intravascular and intracardiac parts
    • Local signs of infection followed by fevers, chills, malaise, fatigue, or anorexia
    • Erosion of any part of the device suggests contamination of the entire system
  • Can be early (within 6 months) or late (more than 6 months)
    • Early is more likely to present with pocket infection
    • Late more often has bacteremia and endocarditis

Investigations

  • Blood cultures, ideally before antibiotics
  • Transesophageal echocardiogram in most cases (in strong preference to transthoracic echocardiogram)
  • Pacemaker pocket swab at time of removal

Management

  • The primary treatment is CIED removal, with adjunctive antibiotics
    • Lead extraction within 3 days of admission is associated with lower mortality

Suspected or Confirmed Pocket Infection

  • If early superficial site infection within 30 days of device placement and without systemic signs like fever
    • Oral antibiotics
  • If clinical signs of pocket infection, need blood cultures and TEE
    • Remove CIED, including generator and all leads
    • If no bacteremia: treat 2 weeks
    • If bacteremia but TEE negative: treat 2 weeks (or 4 weeks for Staphylococcus aureus)
    • If TEE positive: treat 4 weeks if native valve and 6 weeks if prosthetic valve or endocarditis

Suspected or Confirmed CIED Infection

  • Management depends on blood culture findings ± TEE
    • If bacteremia, get TEE
    • If no bacteremia but high clinical suspicion, get TEE
  • If bacteremia (or received prior antibiotics)
    • Valve vegetation ± bacteremia: remove CIED and treat as endocarditis
    • Lead vegetation ± bacteremia: remove CIED and treat for 2 weeks, or 4 weeks for Staphylococcus aureus
    • Negative TEE: consider CIED removal depending on microbiology and treat for 2 weeks
  • If no bacteremia
    • TEE positive: treat as above
    • No TEE or TEE negative
      • Pocket site infection or erosion: remove CIED and treat for 2 weeks
      • No pocket site infection: monitor

Bacteremia Without Focus

Reimplantation

  • After device removal, patients who are pacemaker- or defibrillator-dependent should have a temporary device inserted
    • Epicardial pacing is associated with higher mortality
  • For isolated pocket infection, it is reasonable to reimplant on the same day
  • For all others, reimplantation of a permanent device should be delayed until:
    • Blood cultures are negative at 72 hours, and
    • All source control is complete (such as drainage of deep abscesses, etc.)
  • The device should be reimplanted at a site distant from the first

Further Reading

  • 2017 HRS expert consensus statement on cardiovascular implantable electronic device lead management and extraction. Heart Rhythm. 2017;14(12):e503-e551. doi: 10.1016/j.hrthm.2017.09.001

References

  1. ^  Muhammad R. Sohail, Daniel Z. Uslan, Akbar H. Khan, Paul A. Friedman, David L. Hayes, Walter R. Wilson, James M. Steckelberg, Sarah Stoner, Larry M. Baddour. Management and Outcome of Permanent Pacemaker and Implantable Cardioverter-Defibrillator Infections. Journal of the American College of Cardiology. 2007;49(18):1851-1859. doi:10.1016/j.jacc.2007.01.072.