Background

  • Includes left ventricular assist device (LVAD) infections

Microbiology

Risk Factors

Clinical Manifestations

  • Driveline site infection is the most common with or without other sites of infection, including pocket infection, mediastinitis, pump or cannula infection, endocarditis, and bacteremia
  • Driveline site infection will have local signs and symptoms of infection
  • Pocket infection will present similarly to CIED pocket infection
  • Mediastinitis has fever, chest pain, sternal wound dehiscence or drainage, leukocytosis, and bacteremia

Investigations

  • Blood cultures
  • Aspirate and culture of any fluid collections
  • Ultrasound, CT, or MRI of the chest and abdomen should be considered with bacteremia of unknown source
  • Cultures from any removed hardware

Management

  • Control control, ideally, with removal of the infected device
  • If source control is not possible (which is common), then prolonged antibiotics to suppress infection until heart transplant