Coagulase test: Difference between revisions
From IDWiki
No edit summary |
No edit summary |
||
Line 4: | Line 4: | ||
**Checks for agglutination after a drop of plasma is combined with a suspension of the bacteria on a slide |
**Checks for agglutination after a drop of plasma is combined with a suspension of the bacteria on a slide |
||
**Positive if clumping is apparent within 10 seconds or less, and no clumping is observed in saline or water |
**Positive if clumping is apparent within 10 seconds or less, and no clumping is observed in saline or water |
||
− | **A few species of [[coagulase-negative staphylococci]] may be positive due to membrane-bound clumping factor |
+ | **A few species of [[coagulase-negative staphylococci]] may be positive due to membrane-bound clumping factor |
+ | ***[[Staphylococcus lugdenensis]], [[Staphylococcus schleiferi]] subsp. ''schleiferi'', [[Staphylococcus sciuri]] subsp. ''carnaticus'', [[Staphylococcus sciuri]] subsp. ''rodentium'', and [[Staphylococcus intermedius]] |
||
**[[Staphylococcus aureus]] is negative in 15% of tests, especially MRSA, so negative results need to be confirmed with tube coagulase |
**[[Staphylococcus aureus]] is negative in 15% of tests, especially MRSA, so negative results need to be confirmed with tube coagulase |
||
*'''Tube coagulase''' |
*'''Tube coagulase''' |
||
**Mix a heavy inoculum of bacteria into a tube filled with rabbit plasma |
**Mix a heavy inoculum of bacteria into a tube filled with rabbit plasma |
||
**Positive if clot is formed within 4 hours when incubated at 37ºC |
**Positive if clot is formed within 4 hours when incubated at 37ºC |
||
− | **A few species of [[Coagulase-negative staphylococci]] may be positive |
+ | **A few species of [[Coagulase-negative staphylococci]] may be positive: [[Staphylococcus intermedius]], [[Staphylococcus saccharolyticus]], and [[Staphylococcus schleiferi]] |
[[Category:Diagnostics]] |
[[Category:Diagnostics]] |
Revision as of 18:31, 23 August 2020
- Used to differentiate Staphylococcus aureus from less pathogenic coagulase-negative staphylococci
- Tests for the ability of the organism to convert fibrinogen into fibrin (that is, to form a clot)
- Slide coagulase
- Checks for agglutination after a drop of plasma is combined with a suspension of the bacteria on a slide
- Positive if clumping is apparent within 10 seconds or less, and no clumping is observed in saline or water
- A few species of coagulase-negative staphylococci may be positive due to membrane-bound clumping factor
- Staphylococcus lugdenensis, Staphylococcus schleiferi subsp. schleiferi, Staphylococcus sciuri subsp. carnaticus, Staphylococcus sciuri subsp. rodentium, and Staphylococcus intermedius
- Staphylococcus aureus is negative in 15% of tests, especially MRSA, so negative results need to be confirmed with tube coagulase
- Tube coagulase
- Mix a heavy inoculum of bacteria into a tube filled with rabbit plasma
- Positive if clot is formed within 4 hours when incubated at 37ºC
- A few species of Coagulase-negative staphylococci may be positive: Staphylococcus intermedius, Staphylococcus saccharolyticus, and Staphylococcus schleiferi