Differential time to positivity

From IDWiki
(Redirected from DTTP)
  • Laboratory marker to help identify central line infections
  • Defined as having growth at least 2 hours earlier from a catheter when compared to a paired peripheral blood culture
  • In one metaanalysis, it has a sensitivity of 81% and specificity of 92%, so better as a rule-in test than a rule-out test[1]